InnerVault

PLC Fault Tracer From an Operator Symptom

Indexedprompts.chat (CC0 prompt collection), Markus864

I want you to act as a controls troubleshooter. An operator reported this symptom: "${Operator symptom:Conveyor 3 starts, then drops out after a few seconds}". Platform: ${Platform and version}. I am pasting the source…

Open the source (opens github.com) https://github.com/f/prompts.chat

What it is

Prompts from Markus864.

The problem it solves and who it suits haven't been reviewed by InnerVault. The description above is the source's own.

The prompt

Fill in before using: ${Platform and version} ${Tag that misbehaves:the motor run output} ${Paste block sources} ${Paste I/O list}

I want you to act as a controls troubleshooter. An operator reported this symptom: "${Operator symptom:Conveyor 3 starts, then drops out after a few seconds}". Platform: ${Platform and version}. I am pasting the source of the blocks, routines or POUs involved, the calling order from the main task, and the I/O list.

Start from the output or fault that misbehaves, ${Tag that misbehaves:the motor run output}, and trace it backward across every block. Give a table:
Hop | Block / routine / network / line | Exact condition for this hop | Tag I must watch online to confirm it

Then:
1. List every write to each tag in the chain, in every block, including both branches of every IF and writes that happen after a block call.
2. Say which block calls which, and whether any call is conditional.
3. Rank your top 3 hypotheses for the symptom, each with one read-only check that would confirm or rule it out.
4. List what you cannot see from this code: HMI writes, network or comms partners, forces, hardware configuration, blocks I did not paste.
Do not propose a fix yet. I will send back live values for your watch list first.

=== CODE (all blocks involved) ===
${Paste block sources}

=== I/O LIST ===
${Paste I/O list}

Written by the prompts.chat (CC0 prompt collection) community (Markus864). Not tested by InnerVault.

How to get it

Setup steps: not applicable.

Related

  1. I want you to act as a technical translator for PLC programs. Below are comments, tag descriptions and alarm texts from a PLC or HMI project written in ${Source language:Italian}. Translate them to ${Target…

    Indexed prompts.chat (CC0 prompt collection), Markus864 CC0-1.0

  2. Programming Logic Controller PLC interview questions and answers practical interview industrial based. Siemens PLC and ABB PLC models Q and A. PLC working in Cold Rolling Mill interview questions and answers.

    Indexed prompts.chat (CC0 prompt collection), skillsubhasis@gmail.com CC0-1.0

  3. I want you to act as an experienced drives technician. A variable frequency drive tripped. Drive: ${Drive make, model and firmware if known}. Fault code and text on the keypad: ${Fault code and text}. Motor: ${Motor…

    Indexed prompts.chat (CC0 prompt collection), Markus864 CC0-1.0

  4. I want you to act as a senior controls technician reading a PLC program I did not write. Platform: ${Platform and version:any IEC 61131-3 platform}. Language: ${Language:Ladder}. Below is the code as text, followed by…

    Indexed prompts.chat (CC0 prompt collection), Markus864 CC0-1.0

  5. I want you to act as a strict reviewer of PLC code written by an AI, before it is downloaded to a controller. Platform: ${Platform and version}. Language: ${Language}. Below are my numbered requirements, then the code…

    Indexed prompts.chat (CC0 prompt collection), Markus864 CC0-1.0

  6. I want to find company which deal with plc ,scada, hmi work which company has less employees which are located out side of india find them on linkdin